Book a demo
Pallet labeller stops: count, price and fix SSCC label downtime

Pallet labeller stops: count, price and fix SSCC label downtime

A 14-minute pallet labeller stop blocked two filling lines for 9 minutes. How to count SSCC label stops, track first-time read rate and price each fix.
Pallet labeller stops: count, price and fix SSCC label downtime

In short

  • The label is not the main cost: the cost is the fillers that stop once the labeller holds a pallet longer than the buffer behind it. In the example, a 14-minute stop blocks both filling lines for 9 minutes.
  • Log blocked minutes against the labeller cause: a filler that waits for the end of line should carry the reason "blocked: labeller: data missing", not just "downstream".
  • Track first-time read rate: pallets with both labels right first time, divided by pallets labelled. 96.8% in the example means 10 pallets a shift handled twice.
  • Data errors beat hardware: missing order data caused 9 of the 12 blocked minutes in the example. A second labeller would not have saved them.
  • Fix in order of cost: data release and planned roll changes first, warnings and an outfeed scanner next, then buffer, and a second labeller last.

A print-and-apply pallet labeller stops for a short list of reasons: label stock or ribbon runs out, the pad misses, the printhead wears, the scanner cannot read the barcode, or the order data and SSCC never reach the printer.

Each stop holds a wrapped pallet in the station. Once the pallet places and case conveyor behind it fill, the fillers stop too.

This page shows how to count those stops so the blocked minutes land on the right cause, what a readable GS1 logistic label needs, a failure-mode table with floor checks and owners, and a priced example from a detergent plant. It ends with a decision: more buffer, a second labeller, or neither.

Why one labeller stop reaches the fillers

On an FMCG end-of-line layout the order is fixed. Fillers and case packers feed a case conveyor, the palletiser builds the load, the stretch wrapper wraps it, and the labeller prints and applies the logistic label on two adjacent sides. The labeller is last, so nothing after it can absorb its stop.

What protects the fillers is buffer: free pallet places between palletiser and labeller, plus the cases the conveyor can hold before the palletiser. Divide each by the flow rate and you get minutes. A stop shorter than those minutes costs some attention. A longer one blocks the line all the way back.

One 14-minute labeller stopLabeller stops: no datamin 02 free pallet places fillmin 0-3Palletiser off, cases queuemin 3-5Fillers 1 + 2 blockedmin 5-149 blocked minutes per line= 6 pallets not madeBuffer was 5 minutes
Example line: 2 free pallet places (3 minutes at 40 pallets an hour) plus 2 minutes of case conveyor. A 14-minute labeller stop blocks both fillers for 9 minutes.

Two side effects matter. Short stops drain the buffer, so a second stop soon after the first blocks sooner. And after any stop, the end of line must run faster than the fillers to refill the buffer; the page on starvation and blocking in line balance covers that sizing.

Track OEE and downtime in real time
Book a demo

Pallet labeller failure modes: symptom, cause, check, fix, owner

The table groups labeller stops into eight failure modes. The table pairs each symptom with the check that confirms it on the floor and the person who owns the fix. Tape it to the labeller guard and add your own rows after two weeks of logging.

SymptomLikely causeFloor checkFixOwner
Label roll runs out mid-palletNo low-roll warning; change left to chanceRoll diameter at shift startChange at a set diameter, in a pallet gapOperator
Ribbon out, wrinkled or snappedRibbon not matched to label width or roll length; tensionUsed ribbon: creases, gapsMatch ribbon to stock; set tensionOperator
Faded print, white lines in barsDirty or worn printhead; heat too lowSame white line on every labelClean at each ribbon change; replace worn headMaintenance
No label on the palletPad vacuum lost; pallet out of reach; label stuck to padLabel left on the pad after the cycleSet the pallet stop position; clean vacuum holesMaintenance
Label crooked or wrinkledApplied over a loose film tail; pad pressureLabel sits on the film tailTuck the film tail away from the label zoneMaintenance
Scanner no-readLow contrast, thin bars, label too near an edgeVerifier grade; X-dimension in the templateWider bars; 50 mm from the edgeQuality
Wrong or missing dataOrder not released; wrong template; SSCC not issuedFirst label against the orderRelease data before order start; lock templatesPlanning and IT
Label hidden or at the wrong heightLabel under the wrap; height not set for low loadsBarcode 400-800 mm up, on top of the filmLabel after wrapping; height per pallet typeEngineering

Two rows are not machine faults at all. Roll-outs and data errors are process failures. In the example below they cause the longest stops, because nobody is ready for them, while the hardware faults are shorter and more frequent.

The product matters too. In powder plants, check printheads, sensors and pad vacuum holes for dust, and put the cleaning interval in the standard work. On liquid lines, a leaking bottle can wet the film where the label lands. Both show up as "label crooked" or "no-read" unless someone checks the face of the pallet.

What a readable SSCC pallet label needs

The rules come from the GS1 Logistic Label Guideline (release 1.3). The core is short. The SSCC is the only mandatory element. It is encoded in a GS1-128 barcode with Application Identifier (00), and it sits in the lowest barcode on the label.

GS1 Belgium & Luxembourg calls the SSCC the link between the physical logistic process and the digital information process. For mixed pallets the SSCC on the label is enough, and the rest travels in the despatch advice (DESADV). That link is why a wrong SSCC hurts more than a crooked label.

RequirementGS1 ruleFloor check
Data carrierSSCC in GS1-128, AI (00), lowest barcodeScan shows (00) plus 18 digits
Bar width (X-dimension)0.495-0.94 mm; target 0.495 mmTemplate setting matches
Bar heightAt least 31.75 mm, text not includedRuler on one label per roll
Quiet zonesAt least 10 X on each sideNothing printed close to the bars
OrientationPicket fence: bars uprightLook at the pallet face
Text under barsAt least 3 mm highRuler
Label sizeA6 (105 x 148 mm) or A5 (148 x 210 mm) usualStock spec
Height on palletBarcodes 400-800 mm from the baseTape marks on the station frame
Edge distanceAt least 50 mm from any vertical edgeLabel clear of the corner
SidesSame data on two sides, recommendedBoth labels scan the same SSCC
Print qualityGrade 1.5 (C), 10 mil aperture, 670 nmVerifier report per roll or shift

The two-sides rule exists so one label is always visible, whether the pallet is stored long or short edge facing. GS1 UK puts it as one label on a short side and one on a long side. The guideline adds a practical note: most forklift drivers are right-handed, so labels to the right of each face scan most easily.

The print quality line comes from the GS1 symbol quality table, quoted in GS1 change notice WR 14-163: GS1-128 for SSCC at grade 1.5 (C) on a 4.0 scale. A handheld scanner answers yes or no. A verifier gives the grade and says which parameter is failing.

Which parameters matter most? A study of high-speed sortation by Billo and colleagues in the Journal of Manufacturing Systems found read rate significantly affected by X-dimension, bar growth and symbol contrast. Those are exactly what a worn printhead, wrong heat setting or mismatched ribbon changes.

The guideline also says the upper end of the X-dimension range supports consistent scanning in harsh conditions. It warns against heat-sensitive thermal paper and smudge-prone ink, recommends black bars on white, and lists wrinkling, wrong placement and labels hidden by over-wrapping as the common attaching problems.

How to count labeller stops so the loss lands on the right machine

A labeller that serves two lines is not one machine's problem. Every blocked minute it causes is multiplied by the number of lines behind it. Count six things, per shift:

  1. Labeller stop minutes by reason. Take the start and end from the labeller's fault or not-ready signal; let the operator pick the reason at the machine.
  2. Short stops. Pad misses and reprints of one or two minutes. Nobody writes them on a shift sheet, which is why they need the machine signal. The page on micro-stops covers the counting rules.
  3. Blocked minutes at each filler, with the root cause. The filler's stop should read "blocked: end of line: labeller: data missing". A plain "downstream" reason hides the labeller in every Pareto.
  4. Pallets relabelled by hand, tallied at the dispatch dock.
  5. Pallets flagged or rejected at the customer's DC, from claims and returns.
  6. First-time read rate, explained in the next section.

The blocked-minute link is where the count goes wrong. The filler crew logs "waiting" and the end-of-line operator logs the labeller fault, and nobody joins the two. When you assess equipment downtime tracking software, ask to see a blocked stop carrying its root machine on a line with a shared end of line.

Count the neighbours the same way. The palletiser and stretch wrapper block the fillers by the same mechanism, so give them the same root-cause rule. Film breaks and wrapper losses are covered in the page on stretch wrapper OEE.

One scope note. Product labellers on the primary line are a different machine with different failure modes; the page on labelling machine OEE covers those. This page is only about the logistic label at the end of the line.

First-time read rate: one number for label quality

Stop minutes tell you how often the labeller halts. They do not tell you how many pallets left with a bad label. First-time read rate covers both catches and escapes in one number:

First-time read rate = pallets with both labels applied and read first time ÷ pallets labelled x 100

In the example below, the line labels 312 pallets in a shift. Four needed a reprint after a pad miss, three after a scanner no-read, and three were relabelled by hand at the dock. That is 10 pallets handled twice, so 302 of 312 were right first time: 96.8%.

Split the misses into two groups. Catches are stopped at the labeller and cost a minute or two. Escapes leave the line with a bad label and cost a person, a desk printer and a walk to the dock, or a claim from the customer.

A falling first-time read rate with rising escapes points to the outfeed scanner, not the printer.

GS1 does not publish a target rate. Set your own baseline from two weeks of data, trend it per shift and per label roll, and look at the verifier grade whenever the rate drops. The guideline asks for regular verification once the labeller is in operation, not just at installation.

Worked example: a laundry detergent plant in Belgium

Detergents Europe, the Brussels-based industry body formerly known as A.I.S.E., puts the market value of the European cleaning and hygiene products industry at nearly EUR 50 billion. The numbers below are an example, not a customer's.

  • Line: two liquid filling lines feed one palletiser, one stretch wrapper and one print-and-apply labeller (two labels on adjacent sides).
  • Rate: 40 pallets an hour at peak from both lines together, one pallet every 1.5 minutes.
  • Hours: three 8-hour shifts, 21 production days a month: 63 shifts a month, 756 a year.
  • Buffer: 2 free pallet places (3 minutes) plus 2 minutes of case conveyor: 5 minutes.
  • Crew (sample figures): two operators per filling line, one end-of-line operator.

The shift log below is a sample. Any stop longer than the 5-minute buffer blocks both fillers for the minutes beyond it.

CauseStopsLabeller minutesBlocked filler minutes
Order data not released, no SSCC1149
Label roll ran out172
Ribbon out or wrinkled161
Pad miss, reprint460
Scanner no-read, reprint330
Total103612

Twelve blocked minutes at 40 pallets an hour is 8 pallets not made (12 x 40 ÷ 60). The shift labels 312 pallets instead of 320. Three more pallets are relabelled by hand at the dock, about 6 minutes each, and the customer's DC flags 4 pallets a month (sample).

Labour is priced at EUR 51.50 an hour, the Eurostat labour cost level for Belgian manufacturing in 2024. That is the latest Belgian year in the dataset; the 2025 value is not yet published. Swap in your own rate.

Item and mathsPer shiftPer monthPer year
Blocked crew: 4 operators x 12 min = 0.8 h x EUR 51.50EUR 41.20EUR 2,595.60EUR 31,147.20
Recovery at the labeller: 36 min = 0.6 h x EUR 51.50EUR 30.90EUR 1,946.70EUR 23,360.40
Dock relabels: 3 x 6 min = 0.3 h x EUR 51.50EUR 15.45EUR 973.35EUR 11,680.20
Customer rejects: 4 a month x EUR 150 (sample)EUR 9.52EUR 600.00EUR 7,200.00
Cost paid every shiftEUR 97.07EUR 6,115.65EUR 73,387.80
Lost margin when sold out: 8 pallets x EUR 200 (sample)EUR 1,600.00EUR 100,800.00Sold-out months only

The EUR 150 per rejected pallet is a sample figure for return freight and rework, not a retailer charge. If your customer charges for non-compliant pallets, take the amount from the customer's supplier manual and add it. The EUR 200 contribution margin per pallet is also a sample figure.

Read the table in two layers. The first four rows are paid in every shift: about EUR 73,000 a year of paid time and rework. The last row only applies when every pallet is sold, but then it is 16 times larger per shift than the rest (1,600 ÷ 97.07).

That is why the end-of-line operator's view ("the labeller is a nuisance") and the plant manager's view ("8 pallets lost at peak") may never meet. Both are right, and only the blocked minutes connect them.

Fixes in order of cost

Start with the cheapest fix that removes the largest share of blocked minutes. In the example, the first two items remove all 12.

  1. Release order data before the order starts. A planning rule, no hardware: the order does not start until its label data and SSCCs are on the printer. GS1 expects SSCCs to come from the WMS or ERP; the failure is timing, not the number. In the example this removes 9 of 12 blocked minutes. Owner: planning and IT.
  2. Plan roll and ribbon changes. Change at a set roll diameter during a pallet gap, keep a spare roll at the machine, and match ribbon length to label rolls so both run out together. This removes the other 3 blocked minutes in the example.
  3. Care for the printhead. Clean it at each ribbon change, log every head replacement with its label count, and keep a spare head and pad on the shelf.
  4. Make low label and low ribbon visible. A warning on the stack light, readable from the palletiser, turns a surprise roll-out into a planned change.
  5. Read both labels at the outfeed. A fixed scanner with a reprint or reject path turns escapes into catches. Pair it with a verifier check per roll.
  6. Add buffer where long hardware stops remain after the steps above.
  7. Add a second labeller or a bypass lane only if the labeller itself, not data or process, is still the constraint.

Make the manual fallback safe

Relabelling by hand puts a person at the pallet conveyor and in the forklift path, bending to put barcodes 400-800 mm off the floor. EU-OSHA lists handling loads, awkward postures and repetitive movements among the risk factors for musculoskeletal disorders.

Council Directive 90/269/EEC asks employers to use organisational measures or mechanical equipment to avoid manual handling of loads. On a labelling line that means a fixed relabel station at working height, outside the forklift route, with its own printer and scanner. Rotating a pallet by hand to reach the second face is the task to remove.

More buffer or a second labeller? The decision

Once the cheap fixes are in, the remaining blocked minutes decide the purchase. Each option fixes a different kind of stop.

OptionFixesDoes not fixCost
Process fixes (data release, planned changes)Data errors, roll-outsWorn parts, long faultsStaff time
More buffer before the labellerAny stop shorter than the new bufferLonger stops; needs floor spaceIntegrator quote: conveyor, controls
Second labeller or bypass laneHardware stops on one labellerData errors: both share the same dataHighest: machine, conveyor, controls
Measure first with line softwareShows which option paysNothing on its ownAsk the vendor for a price per line per month

The cheapest way to choose between the first three is to measure first. Production downtime tracking software that reads the labeller, palletiser and fillers from their machine signals shows how many blocked minutes each cause produces before any money goes into conveyor or machines.

What you see: a shift timeline, unclassified time waiting for a reason, and the operator's line-down screen, on sample lines. Book a demo.
Plays from YouTube. Google may set cookies when you press play. Privacy policy.

Two weeks of signal data shows whether data, roll-outs or hardware drive the blocked minutes. Without it, the purchase follows the loudest voice at the morning meeting.

Sizing the buffer

Size the buffer on the stops you want to absorb, not on the average. Take the longest labeller stop you see in a typical week and divide by the minutes per pallet. In the example, moving from 5 to 15 minutes means 10 more minutes, or about 7 pallet places (10 ÷ 1.5 = 6.7).

That 15-minute buffer would have absorbed every stop in the sample shift, including the 14-minute data error. It would not absorb a 25-minute printhead change on a bad night, which is why spare parts on the shelf come before conveyor.

Who should pick which

  • Data errors cause over half the blocked minutes: fix data release first. A second labeller is the wrong purchase.
  • Many short stops, few long ones: standard work, warnings and an outfeed scanner. Buffer and a second machine will not pay.
  • Long hardware stops remain and floor space exists: add buffer before the labeller.
  • One labeller serves several lines, cycle time is tight at peak, and there is no space for buffer: a second labeller or a bypass lane with a manual relabel station.

Questions to ask the integrator or software vendor

  1. What is the labeller's cycle time for two labels on adjacent sides at the label size in use, and how much margin does that leave at peak rate?
  2. Does it give low-label and low-ribbon warnings, and can the line PLC read them?
  3. What happens when the outfeed scanner cannot read a label: reprint, reject lane or stop?
  4. How does label data reach the printer, and what does the labeller do when the order data or SSCC is missing?
  5. Which spare parts belong on the shelf (printhead, pad, vacuum parts), and what are their lead times?
  6. For software: can a filler's blocked stop carry the labeller and its reason as the root cause?
  7. For software: what is the price per line per month, and which machine signals are needed?

A floor card for the first two weeks

Before buying anything, run the counting for two weeks. The card below fits on the labeller guard and the dock desk.

Six-step floor card for pallet labeller stops: log reasons, tag blocked time, count relabels, read rate, price, fix
Floor card: two weeks of counting before any purchase decision on the end-of-line labeller.
Text version of the diagram
  1. Log every labeller stop with a reason at the machine: label roll, ribbon, pad, no-read, data, printhead. Short stops count too.
  2. Tag blocked time to the labeller: when fillers wait on the end of line, the reason is the labeller cause, not "downstream".
  3. Count relabels and rejects: pallets relabelled at the dock and pallets flagged by the customer.
  4. Work out first-time read rate: pallets right first time divided by pallets labelled, trended per shift.
  5. Price the week: blocked minutes times crew cost, relabel minutes, rejects and lost pallets.
  6. Fix the biggest cause first: data and roll-outs before hardware, then buffer, then a second labeller.

Keep the counting rules fixed for the two weeks. If the reason list changes halfway, the before-and-after comparison is lost.

Where Fabrico fits

  • OEE by line and shift from the core machine, read through the line PLC or a Fabrico IoT device.
  • Micro-stops from the machine signal; when the labeller blocks the line, the operator logs the labeller cause as the stop reason, set up as a blocked reason in the list.
  • Stop reasons chosen by the operator at the machine in a few taps, such as "label roll out" or "data missing".
  • With price and margin entered, losses are priced in money and stops are ranked by financial impact.
  • Where a station has no usable signal, the camera add-on counts output, for example pallets leaving the line.
  • A work order from a logged stop in one tap, for example a printhead replacement.

Fabrico does not verify labels, grade barcodes or generate SSCCs (see label and code vision versus an OEE camera); those stay with the labeller, the verifier and the ERP or WMS. Fabrico is made by the publisher of this article. See OEE software for consumer goods and OEE with computer vision.

Sources, accessed 26.11.2026: GS1, Logistic Label Guideline, release 1.3; GS1, General Specifications change notice WR 14-163; GS1 Belgium & Luxembourg, GS1 Logistics Label; GS1 UK, Pallet label best practice; Billo et al., Impact of bar code print quality on the performance of high-speed sortation systems, Journal of Manufacturing Systems 22(4), 2003; Eurostat, Labour cost levels by NACE Rev. 2 activity (lc_lci_lev); Detergents Europe (formerly A.I.S.E.); EU-OSHA, Musculoskeletal disorders; EUR-Lex, Council Directive 90/269/EEC on manual handling of loads.

Frequently asked questions

Why does a pallet labeller stop the whole line?

It is the last machine, so a stopped labeller holds a pallet in the station. Once the free pallet places and the case conveyor fill, the palletiser and then the fillers are blocked. The buffer in minutes decides how long a stop can last before that happens.

How many SSCC labels does a pallet need?

The GS1 Logistic Label Guideline asks for at least one label and recommends the same data on two sides, so one label is always visible. GS1 UK describes this as one label on a short side and one on a long side.

What print quality does an SSCC barcode need?

The GS1 symbol quality table lists GS1-128 for SSCC at grade 1.5 (C) on a 4.0 scale, with a 10 mil aperture and 670 nm light. Check it with a verifier, not only a handheld scanner, at regular intervals.

What is a good first-time read rate for pallet labels?

GS1 publishes no target. Measure two weeks as a baseline, trend it per shift and per label roll, and treat every escape that reaches the dock or the customer as more costly than a reprint at the labeller.

Should the labeller sit before or after the stretch wrapper?

Labelling after wrapping keeps the film off the barcode. GS1 lists labels obscured by over-wrapping among the common attaching problems, so a label applied before the wrapper needs a check that the film never covers it.

Can a customer charge for a pallet with a bad label?

Charges, if any, are set in each customer's supplier manual or contract, not by GS1. Ask the customer for the current supplier manual and price relabels and rejections from it.

How much buffer belongs before the labeller?

Take the longest labeller stop you want to absorb and divide it by the minutes per pallet. At 40 pallets an hour, each extra 1.5 minutes of buffer is one pallet place.

See labeller stops and blocked minutes priced in money. A demo shows OEE by line and shift from the core machine, stop reasons logged at the machine, and losses ranked by financial impact.

Book a demo

Track OEE and downtime in real time
See where lines lose time
Book a live demo.
See where lines lose time
See where lines lose time

Real Fabrico tiles, sample data.

By clicking the Accept button, you are giving your consent to the use of cookies when accessing this website and utilizing our services. To learn more about how cookies are used and managed, please refer to our Privacy Policy and Cookies Declaration