Consumer Product Recalls Tracker: CPSC and Safety Gate Cases by Defect
In short: A consumer product recall notice names the units it covers by model, by a date code or serial range, or by a mark on the product, and it states a unit count. How tight that range can be is decided before the recall, by the maker's production record. This tracker sorts each month's CPSC recalls and EU Safety Gate alerts of manufactured consumer goods by the defect the notice states, and reads each one for the record that bounded it.
- From 1 August to 18 November 2026 the CPSC published 165 recalls; 92 cover durable consumer goods (appliances, furniture, tools, household goods). 53 state a design or component failure, 35 a failed mandatory standard and 3 a production or assembly escape.
- 68 of the 92 notices bound their units by model only. 21 use a date code, production dates or a serial or batch range, and 3 a mark on the unit.
- Example plant: the same crimp fault covers 31,348 heaters by the line record, 73,816 by a monthly date code and 163,702 by shipping dates. At the US$70 to US$110 retail price in a CPSC heater notice, the refund exposure runs from US$2,194,360 to US$18,007,220.
Tracker, updated 18 November 2026. Next update: December 2026, with the notices published since. Sources are listed at the end.
The range in a recall notice comes from the record kept by OEE software by machine, line and shift, joined on the line and the time to the genealogy in the ERP or traceability system (the trade-offs are in lot vs serial tracking). A recall notice is written after the fact, but its costliest line is decided long before: the line that says which units are affected. When a maker can show that a fault entered production at one changeover and left it at another, the notice can name a date code range. When it cannot, the notice names the model, and every unit ever sold is in scope. The difference is the production record: which product ran on which line, when, how many good units it made, and where it stopped and changed over. This page logs the notices each month, explains the US and EU rules in the sequence they apply, and prices three ways of drawing the same range for an Example plant.
Consumer product recalls, August to November 2026, sorted by stated defect
The rows come from the CPSC recalls database, queried on 18 November 2026 for recall dates from 1 August to 18 November 2026: 165 recalls. Of these, 92 cover durable manufactured consumer goods. The other 73 are toys and children's products, apparel, vehicles and bicycles, sports gear, and chemicals or packaging, and are counted but not sorted here.
The sort rule, printed so the next update uses the same one: each notice goes in the class its own hazard sentence states. “Fails a mandatory standard” when the notice says the product violates a mandatory standard, ban or federal rule. “Production or assembly escape” when it says a part was installed incorrectly, was missing or was assembled wrongly at manufacture. “Use and warnings” when the remedy is a label or a change in use. Everything else that breaks, shorts, overheats or ignites is “Design or component failure”. A word sort is a first cut: a component failure can still have a production cause the notice does not state.
| Stated defect | Recalls | Units in the notices | Median units per recall | Remedy offered |
|---|---|---|---|---|
| Design or component failure | 53 | 14,616,741 | 8,709 | Refund 30, repair 14, replace 6, a choice 3 |
| Fails a mandatory standard | 35 | 389,504 | 1,738 | Refund 30, repair 4, a choice 1 |
| Production or assembly escape | 3 | 22,952 | 3,992 | Repair 3 |
| Use and warnings | 1 | 5,900,000 | 5,900,000 | Repair (a spoon and a label) 1 |
| All 92 | 92 | 20,929,197 | Refund 60, repair 22, replace 6, a choice 4 |
Source: CPSC recalls database, recall dates 1 August to 18 November 2026, sorted by the rule above. Units are the United States figures printed in each notice; Canadian units are excluded. “A choice” means the notice offers more than one of refund, repair and replace.
The same 92 notices sorted by how they bound their units:
| How the notice names the units | Recalls | Units | What the maker's record had to supply |
|---|---|---|---|
| Model or part number only | 68 | 15,558,776 | Nothing finer than the model: every unit sold is in scope |
| Production dates or a date code range | 10 | 583,642 | The first and last affected build, by date |
| Serial, batch or code range | 11 | 1,113,579 | The serials or batches built while the cause was present |
| A mark on the unit | 3 | 3,673,200 | A change applied at a known point, visible on the product |
Three readings follow from the two tables, and the rest of the page builds on them.
- A failed standard covers the whole model. 26 of the 35 standard failures name the model only, because a product that fails a standard by design fails it in every unit. No production record narrows a dresser that tips without a wall anchor.
- A production cause is rare in the wording and narrow in the scope. Only 3 notices state an assembly escape, and two of them give the build window to the day. Where a cause enters at one point in production, a record of that point is what lets the notice say so.
- The remedy follows the cause. Refunds dominate the standard failures (30 of 35). All three assembly escapes are repairs: the fault sits in the build, so the unit is fixed.
How a US consumer recall starts: Section 15(b), 24 hours and Fast Track
Section 15(b) of the Consumer Product Safety Act, 15 U.S.C. 2064, puts the first move on the maker. Every manufacturer, distributor and retailer of a consumer product that obtains information that the product fails a consumer product safety rule or another rule, standard or ban, contains a defect which could create a substantial product hazard, or creates an unreasonable risk of serious injury or death, “shall immediately inform the Commission”. The CPSC's reporting rule gives the clock.
| Step | Rule | What the plant has to have ready |
|---|---|---|
| 1. Information reaches the firm | 16 CFR 1115.14(b): information should reach the chief executive or the official responsible for reporting in no more than 5 days, the “maximum reasonable time” | A route from field reports and warranty returns to the person who decides |
| 2. Investigation | 16 CFR 1115.14(d): an investigation should not exceed 10 days, unless a longer period can be shown to be reasonable | Production dates, build counts and changeovers for the suspect period, found in days rather than weeks |
| 3. Report | 16 CFR 1115.14(e): “Immediately” means within 24 hours of obtaining information that reasonably supports the conclusion that a report is due | An initial report naming the product and the hazard |
| 4. Full report | 16 CFR 1115.13(d): model numbers, serial numbers and date codes; the total number of units; the dates units were manufactured, imported, distributed and sold; the units at each level of distribution and with consumers; the corrective action | The range, its count, and where the units are now |
| 5. Remedy | 15 U.S.C. 2064(d): repair the defect, replace the product with a like or equivalent product, or refund the purchase price, less a reasonable allowance for use where the consumer has had it a year or more | Repair parts or replacement units for the count in step 4, or the cash for refunds |
Weekends and holidays are excluded from these periods (16 CFR 1115.14(a)). The step a plant can shorten is step 2. Ten days is enough to read a production record that exists; it is not enough to rebuild one from paper travellers and shift notes.
The CPSC's Fast Track program is the faster path. A firm that reports and is ready to put a corrective action plan into effect “within 20 working days” can recall without the staff making a preliminary determination that the product contains a defect which creates a substantial product hazard, and it must stop sale and distribution at once (CPSC Fast Track page). Products that may violate mandatory standards are not handled through Fast Track. Of the eight notices in the case notes below, four carry the “Fast Track Recall” label (Cummins, Lithonia, Char-Broil, AGA Rangemaster); the standard failure among them (Mainstays dressers) does not.
Twenty working days from report to an approved plan means the range has to be known before the report. That is the practical reason to keep the production record at a grain finer than the model: when a firm takes the Fast Track route, the range in its plan is the range its records could support in those four weeks.
Repair, replace or refund: what each remedy costs the maker
The remedy is chosen with the range, and the range sets its size. A refund is paid on every unit the consumer returns or destroys; a repair needs a part and labour per unit; a replacement needs a new unit from the line. In the 92 notices:
- Refund in 64 notices (alone in 60). Refund notices such as Daikin's, 3M's and Designs Direct's ask the consumer to cut the cord and send a photo first. The refund is then a cash cost per unit in the range, at the price paid.
- Repair in 23 notices (alone in 22). Repairs range from a kit by mail (Char-Broil's screws, wrench and label; Branch's backrest and bolts) to a technician at the home (AGA Rangemaster ranges, Ariston boilers, Sauna360 rooms).
- Replace in 10 notices (alone in 6). DREO replaces each heater in its range; Bose replaces the battery pack, not the speaker; Cooluli sends a new power cord and a sticker for the unused port.
The EU rule pushes the same way. Under Article 37 of the General Product Safety Regulation (EU) 2023/988, applied from 13 December 2024, the recalling operator offers the choice between at least two of repair, replacement with a safe product of the same type, and an adequate refund of the value, with the refund at least equal to the price paid. The EU notice has to identify the product by identification numbers “such as batch or serial number” (Article 36), and the manufacturer has to put a type, batch or serial number on the product in the first place (Article 9(5)).
The remedy does not change the count; it changes the price per unit of the count. A range that is too wide costs a refund, a part or a new unit for every product that never had the fault.
Units in commerce, units sold: the count in the notice
The “Units” line of a CPSC notice is one number, but 16 CFR 1115.13(d)(9) asks the firm for the count by where the units are: with the manufacturer or importer, private labelers, distributors, retailers, and consumers. Units still in the plant, a warehouse or a retailer's stock are stopped and held; only units with consumers need the public notice to reach them. The notices show three ways the count goes wrong.
- Units that leave after the recall. Walmart's reannouncement of 27 August 2026 says Mainstays nine-drawer dressers, about 165,250 in all with about 165,000 recalled in May 2026, were sold to consumers after the recall through four liquidators. Returned or held stock is still in commerce until it is destroyed.
- Units built before they were sold. Branch's chairs were built from 10 September 2025 and sold from about December 2025. The first three months of the range sat in stock, and those units were the cheapest to correct.
- Units counted across borders. Notices for products also sold in Canada give those units separately: DREO about 36,300 beside 338,800, Bose about 35,400 beside 634,759. A plant that ships one build to several markets holds one record, and several recalls draw on it.
Production window against sales window: eight notices
The comparison this tracker is built on. Each row states the production window the notice gives, the sales window it gives, and the ratio of their lengths in months. Where a notice gives only a sales window, a range drawn from sales or shipping dates is the only one available.
| Notice (date) | Product | Production window in the notice | Sales window in the notice | US units |
|---|---|---|---|---|
| Cummins, 27-087 (12 Nov 2026) | Dual fuel portable generators | None: model and part number only | May 2025 to Aug 2026, 16 months | About 2,960 |
| DREO, 27-054 (29 Oct 2026) | Ceramic space heaters | Apr 2025 to Jan 2026, 10 months | Sep 2025 to Oct 2026, 14 months | About 338,800 |
| Lithonia Lighting, 27-041 (22 Oct 2026) | Luminaire tilt arm mounts | Aug 2019 to Jul 2020 and Aug 2024 to Apr 2026, 33 months in two windows | Aug 2019 to Aug 2026, 85 months | About 11,532 |
| Char-Broil, 26-773 (17 Sep 2026) | Electric grills | Date codes 2510 to 2512, 3 months | Oct 2025 to Jun 2026, 9 months | About 10,605 |
| AGA Rangemaster, 26-756 (10 Sep 2026) | Dual fuel ranges | 19 Mar 2025 to 24 Jul 2026, to the day | Mar 2025 to Jul 2026, 17 months | About 3,992 |
| Branch, 26-735 (3 Sep 2026) | Ergonomic chairs | 10 Sep 2025 to 22 Apr 2026, to the day | About Dec 2025 to Jul 2026, 8 months | About 16,000 |
| Walmart Mainstays, 26-726 (27 Aug 2026) | Nine-drawer fabric dressers | Sep 2023 to Dec 2025, 28 months | Sep 2023 to Mar 2026, 31 months | About 165,250 |
| Little Giant, 27-067 (5 Nov 2026) | Ladders with Rapid Locks | None by date: units without an orange “QC” sticker | Dec 2015 to Oct 2026, 131 months | About 3,662,000 |
Source: the CPSC notices linked in the case notes below. Months are counted inclusive of the first and last month named. The recall number's first two digits are the CPSC fiscal year, which starts on 1 October, so 27-054 was published in October 2026.
Of the six rows with both windows, the sales window is longer in four, because a build is sold over months after it leaves the line. At AGA Rangemaster and Branch the two have the same length in months, but Branch's sales start about three months after its first build. Lithonia's case is the clearest: 33 months of production spread across 85 months of sales. A range drawn from sales dates would have covered every mount sold in seven years.
Case notes, newest first
Each note ends with what its own notice tells a plant to check. New notices are added at the top, with the recall date and number.
Cummins generators, 12 November 2026 (27-087): an assembly escape bounded by part number
The Cummins notice covers about 2,960 Onan P5000iDF EFI dual fuel portable generators, made in Vietnam and sold from May 2025 through August 2026 for US$1,640 to US$1,930. It states the cause plainly: the valves “were installed incorrectly”, so fuel vapor cannot vent from the gasoline tank and pressure can eject the fuel cap. Owners check the model and part number on the side label against a recall page; the remedy is a free repair at a service location, and the notice is a Fast Track recall. Cummins has received eleven reports of fuel discharging or the cap ejecting.
- An installation error has a start. Incorrectly installed valves came from an assembly step at a point in time. Units are identified by part number, not by build date, so the notice cannot say when that step went wrong.
- Put a build date where the owner looks. The model and part number are already on the side label. A build date or serial on the same label is what a narrower range would need.
Little Giant ladders, 5 November 2026 (27-067): a sticker as the dividing line
The Little Giant notice covers about 3,662,000 ladders with Rapid Locks across eleven model families, sold from December 2015 through October 2026, made in the United States, China, Mexico and Malaysia. Ladders can retract if a Rapid Lock is not fully engaged; the firm has 25 reports of retraction, with 19 injuries. “Only ladders without an orange rectangular QC sticker” on the rail above a lock are included. The remedy starts with warning labels and instructions; a lock that still fails after lubrication goes to evaluation, then a replacement or a refund from a depreciated value up to the full price for ladders bought in the past 12 months.
- A mark at the change point splits 131 months of sales. The sticker separates units that passed a check from those that did not, without any date. A plant that changes a process mid-run can apply such a mark from the first unit made the new way.
- Depreciation shrinks the refund, not the count. All 3,662,000 units stay in scope; only the price per unit falls with age, as 15 U.S.C. 2064(d) allows after a year.
DREO space heaters, 29 October 2026 (27-054): a ten-month window by month code
The DREO notice covers about 338,800 DR-HSH015 ceramic space heaters, plus about 36,300 in Canada, made in Vietnam. “Only units manufactured from April 2025 through January 2026 are included”; the manufacture date is printed in YYYY/MM format on a label under the heater. They were sold from September 2025 through October 2026 for between US$70 and US$110. Heaters can overheat and ignite; DREO has 17 reports, three with property damage and one burn injury. The remedy is a free replacement heater, after the owner cuts the cord and sends a photo.
- The label's grain is the range's grain. A YYYY/MM code can only say “April 2025 through January 2026”. If the cause ran for part of April or part of January, those whole months are in the range.
- A replacement is a production run. Replacing up to 338,800 heaters is a build plan on the line that made them. The size of that run is the size of the range.
Lithonia Lighting tilt arms, 22 October 2026 (27-041): two windows, one notice
The Lithonia Lighting notice covers about 11,532 RSX luminaires with AASP, AARP, AAWB and AAWSC adjustable tilt arm mountings, made in the United States and Mexico and “manufactured between August 2019 to July 2020 and August 2024 to April 2026”. They were sold to commercial distributors from August 2019 to August 2026 for US$400 to US$2,200. The knuckle of the arm can fail and the luminaire can fall; there are 13 reports of arms breaking and four of fixtures falling. A professional replaces the arm assembly, and the notice is a Fast Track recall.
- The record has to allow a gap. Two production windows four years apart mean the cause was present, absent and present again. Only a record by date can exclude the four years between.
- Owners cannot read the window. The notice asks owners to contact Lithonia to confirm whether their mount is included. The maker's record, not the label, decides each unit.
Char-Broil electric grills, 17 September 2026 (26-773): three month codes out of nine months of sales
The Char-Broil notice covers about 10,605 Bistro Pro electric grills, plus 342 in Canada, made in China and sold from October 2025 through June 2026 for US$150 to US$250. The grounding wire for the heating element can disconnect and lose fault protection. Only grills with the four-digit YYMM date codes 2510, 2511 and 2512 are included. The remedy is a repair kit with screws, a screwdriver, a wrench and a label, and a US$25 digital gift card for photo proof of the completed repair. The notice is a Fast Track recall.
- Three months of builds, nine months of sales. A range drawn from sales dates would have run from October 2025 to June 2026. The date code cut it to the builds of one quarter.
- The gift card buys the count. Paying for a photo of the finished repair turns an unknown completion into a counted one, unit by unit.
Book a demo and see OEE and losses per line and shift.
AGA Rangemaster dual fuel ranges, 10 September 2026 (26-756): a missing cap, dated to the day
The AGA Rangemaster notice covers about 3,992 AGA Elise, AGA Mercury and La Cornue CornuFé dual fuel ranges, plus about 336 in Canada, made in the United Kingdom and “manufactured between March 19, 2025 and July 24, 2026”. They were sold through appliance dealers from March 2025 through July 2026 for about US$6,000 to US$20,000. A missing cap on the gas test port can cause a gas leak. Owners look up the serial number on the rating plate; a certified technician repairs each affected range. The notice is a Fast Track recall.
- A missing part is an assembly step. The two dates bound the period in which the cap could be left off, and the second marks the last build in range.
- At US$6,000 a range, the serial carries the decision. With serials on the rating plate, the maker can include or exclude each range, and a technician visit is spent only where the record says.
Branch ergonomic chairs, 3 September 2026 (26-735): a window in which only some units are wrong
The Branch notice covers about 16,000 height-adjustable chairs, plus about 180 in Canada, made in Thailand. It covers only chairs with backrest anchors “incorrectly installed at the time of manufacture”, built between 10 September 2025 and 22 April 2026, with the manufacture date on a label under the seat. They were sold from about December 2025 through July 2026 for US$320 to US$350. Backrests can detach; there are 11 reports. Owners send photos of the label and the removed backrest to get a free repair kit, and Branch is contacting all known purchasers directly.
- The window holds the suspects, not the faults. 16,000 chairs were built in the window, but only those with wrongly installed anchors need the kit. The photo step sorts them after sale.
- Known purchasers are a shorter list. Direct sales give Branch the buyers of each chair. Combined with the build date, that turns a public notice into letters to named customers.
Walmart Mainstays dressers, 27 August 2026 (26-726): a recall that leaked through returns
The Walmart notice reannounces the recall of Mainstays nine-drawer fabric dressers, about 165,250 units, of which about 165,000 were recalled in May 2026. The dressers were made in Vietnam from September 2023 through December 2025, with a tracking or lot number and the manufacture date under the top panel, and sold from September 2023 through March 2026 for about US$80. They are unstable unless anchored and violate the mandatory standard required by the STURDY Act. After the May recall, recalled dressers were sold to consumers through four liquidators. The remedy is a full refund.
- A failed standard takes the whole model. 28 months of production are all in scope, because the design fails in every unit. The date window only confirms the model's life.
- Held stock needs its own hold. Units returned or held after a recall are still units in commerce. A recalled range has to be blocked in the returns and resale flow as well as on the shelf.
Earlier notices from August to November 2026 are in the two sort tables above; a notice gets a case note when it states a production window, a code range or a production cause.
EU Safety Gate: the risk types and what a batch number buys
Safety Gate is the EU rapid alert system for dangerous non-food products. Each alert carries a product category, one or more risk types, the legal provision the product fails, the measures taken and the country of origin. The Safety Gate portal lists 22 risk types: asphyxiation, burns, chemical, choking, cuts, damage to hearing, damage to sight, drowning, electric shock, electromagnetic disturbance, energy consumption, entrapment, environment, fire, other health risk, injuries, incorrect measurement, microbiological, security, strangulation, suffocation and other.
For this edition, 59 alerts in the categories electrical appliances, machinery, lighting, furniture, hand tools, kitchen articles, decorative articles and construction products were read, published from 6 October to 18 November 2026 (weekly reports 40 to 46). They are the alerts in those categories that the portal's list of recent alerts returned on 18 November, not every alert of the period; the next update widens the count.
| What the 59 alerts state | Count | What it means for the range |
|---|---|---|
| Risk type electric shock | 39 | Insulation, creepage and clearance faults: design, so every unit of the model |
| Risk type fire | 7 | Overheating cables, chargers and appliances |
| Fails the Low Voltage Directive | 40 | 29 of the 59 also name a European standard, such as EN 60335-1 |
| Fails the General Product Safety Regulation | 7 | No harmonised standard applies; the general safety duty does |
| A batch number given | 9 | The only alerts in which a range finer than the model can be read |
| Recall from consumers among the measures | 27 | Withdrawal from the market appears in 31, removal from an online marketplace in 15 |
| Country of origin China | 53 | Plus 3 unknown and one each from Czechia, France and Vietnam |
Source: Safety Gate alert records read through the portal on 18 November 2026. An alert can carry more than one risk type and more than one legal provision, so those rows do not sum to 59.
Two alerts show the difference a batch makes. The Hungarian alerts SR/03044/26 and SR/03045/26 name two X-start USB chargers, batches 2507 and 2502, both lacking adequate insulation between the primary and secondary circuits. Two batches with the same fault point to the design, not to the batch, and the batch numbers only identify the units seized. The Irish alert OR/00119/26 names a Tesco Home F&F glass latte mug that “may break unexpectedly during normal use” due to “a manufacturing defect”, recalled from consumers, and identifies it by barcode only. A manufacturing defect is the case in which a batch range would narrow the recall, and it is the case without one.
GPSR Article 9(5) already requires the type, batch or serial number on the product. The production record decides whether that number maps to a period in which the cause was present.
Worked example: three ranges for one crimp fault
Example plant. Every operating figure in this section is Example data; the retail price band, the refund rules and the reporting rules are sourced. The plant and its product are not any company named above.
The Example plant assembles a ceramic space heater, model EH-20 (Example), on two lines. Each heater carries a rating label with a four-digit YYMM date code, like Char-Broil's; units have no individual serial. On line 2, the crimp tool for the thermal cutoff lead is changed at a changeover logged at 14:20 on Tuesday 3 February 2026, second shift. The new tool crimps below its specified height. The fault is found when line 2 runs its first-off approval after the next tool change, logged at 06:40 on Thursday 26 February 2026, first shift, and production on line 2 stops for containment.
Step 1: the range from the line record. The line record holds the product that ran on line 2, the good units by shift and both changeovers. Line 1 made EH-20 with its own crimp tool throughout and is outside the cause.
| Line 2, EH-20 | Good units |
|---|---|
| Tue 3 Feb (from 14:20) to Fri 6 Feb | 9,276 |
| Mon 9 Feb to Fri 13 Feb | 9,402 |
| Mon 16 Feb to Fri 20 Feb | 9,155 |
| Mon 23 Feb to Thu 26 Feb (to 06:40) | 3,515 |
| Range A: line 2, 3 Feb 14:20 to 26 Feb 06:40 | 31,348 |
Example data. 9,276 + 9,402 + 9,155 + 3,515 = 31,348. The date code alone cannot pick these units out of February, so the label needs a mark the owner can read: in this example the plant's genealogy in its ERP links each pallet to its line and shift, and line 2's February pallets carry a pallet label that retailers and the returns centre can check.
Step 2: the range from the date code. Without the line and shift, the narrowest range the label supports is the month code 2602: every EH-20 built in February on both lines, 73,816 units (Example data).
Step 3: the range from shipping dates. Without production dates in the record, the plant can only say which heaters shipped while affected units were shipping: the first line 2 pallet from the window shipped on 9 February and the last on 30 April. Every EH-20 shipped in that span, 163,702 units, is in range C (Example data).
Step 4: price each range. The CPSC's DREO notice of 29 October 2026 gives the retail price of a ceramic space heater as between US$70 and US$110. A refund under 15 U.S.C. 2064(d) is the purchase price, and under GPSR Article 37 at least the price paid; the units are under a year old, so no allowance for use applies. The exposure if every unit in the range is refunded:
| Range | Drawn from | Units | Refund exposure at US$70 | Refund exposure at US$110 |
|---|---|---|---|---|
| A | Line record: line 2, changeover to changeover | 31,348 | US$2,194,360 | US$3,448,280 |
| B | Date code 2602, both lines | 73,816 | US$5,167,120 | US$8,119,760 |
| C | Shipping dates, 9 Feb to 30 Apr | 163,702 | US$11,459,140 | US$18,007,220 |
| B minus A | Cost of the coarse date code | 42,468 | US$2,972,760 | US$4,671,480 |
| C minus A | Cost of having no production dates | 132,354 | US$9,264,780 | US$14,558,940 |
Example units; the US$70 to US$110 price band is from the DREO notice. 31,348 x 70 = 2,194,360; 31,348 x 110 = 3,448,280. 73,816 x 70 = 5,167,120; 73,816 x 110 = 8,119,760. 163,702 x 70 = 11,459,140; 163,702 x 110 = 18,007,220. 73,816 minus 31,348 = 42,468; 163,702 minus 31,348 = 132,354.
Step 5: split range A by where the units are. 16 CFR 1115.13(d)(9) asks for the count by location, and the plant's shipping records give it: 4,183 heaters in the plant and its distribution centre, 6,905 in retailers' stock and 20,260 with consumers (Example data; 4,183 + 6,905 + 20,260 = 31,348). The 11,088 units not yet sold are stopped and reworked, not refunded. The consumer exposure is 20,260 x 70 = US$1,418,200 to 20,260 x 110 = US$2,228,600.
Step 6: read the result. The fault is the same in all three ranges; only the record differs. A plant that can show the two changeovers on line 2 carries US$2.19 million to US$3.45 million of refund exposure, of which US$1.42 million to US$2.23 million sits with consumers. The same plant with only a month code carries up to US$8.12 million, and with only shipping dates up to US$18.01 million. These are exposures, not costs: the share of owners who claim a remedy is lower than the count, and the CPSC tracks it as the correction rate, the share of recalled units “refunded, replaced, or repaired” (GAO-21-56). But the count is what the notice publishes and what the plan has to fund.
Step 7: what to do first. Check that the line record logs every tool change and changeover with the time, the line and the product that ran, and that the plant's genealogy maps pallets to the line and shift. Then check the label: a YYMM code makes the month the smallest range a consumer can read, whatever the record holds.
Two caveats. A replacement remedy costs a new unit rather than the retail price, and a repair kit costs less again, so the dollar figures are the refund case only. Freight, notices, call centre, retailer handling and destruction are not priced.
Date code, shift record or serial: choosing the grain
The cases and the example give five ways to set the grain of a range. They can be combined.
| Option | Choose it if | Cost anchor on this page | Watch for |
|---|---|---|---|
| Model or part number only | The defect is in the design or a standard, so every unit is affected anyway | All 35 standard failures; Mainstays' 28 months all in scope | A production cause, as at Cummins, then has no window to point to |
| Month date code on the label | Volumes are low and changes of tool or supplier are rare | Example range B: US$2,972,760 to US$4,671,480 more exposure than the line record | Whole months in range, as DREO's April and January |
| Day or shift date code plus the line record | Several lines build one model, and tools, fixtures or component lots change within a month | Example range A: US$2,194,360 to US$3,448,280 | A record that misses changeovers; a label the owner cannot read |
| Unit serial with genealogy in the ERP or traceability system | High unit value or a technician remedy, as AGA's US$6,000 to US$20,000 ranges | Not priced here | Serials that are not linked to the line, shift and component lots |
| A visible mark from the change point | A fix or a check is introduced mid-run and owners must tell units apart | Little Giant's QC sticker across 131 months of sales | Marks that are applied inconsistently, or can be lost |
Questions to put to a supplier of line data or traceability software, in writing:
- Is every changeover and tool change logged with its time, line and the product that ran, and can a range be read from changeover to changeover?
- Can the good units of one product on one line be summed between two timestamps, by shift?
- How do line records join to lot, serial or date code genealogy in the ERP: on line and time, and with which keys?
- Can the record show two windows for one product, as Lithonia's notice needed?
- Can the count be split by location (plant, warehouse, retailer, consumer) from the shipping records?
The first-off check that ends the Example window is covered in first-off approval after changeover, and holding suspect stock in quality hold process design.
A plant check for this week and this quarter
Each step produces a number for the next report, or a gap to close before one is needed. Plant, production and quality managers can split them.
This week
- Read the label on each product family: does it carry a model only, a month code, a day code or a serial? Write down the smallest range an owner could read from it.
- Pick one product and one line, and try to sum its good units between two changeovers last month from the line record. Time how long it takes.
- Check that tool changes, fixture changes and component lot changes are logged as changeovers with a time, not only in a notebook.
- Find who receives field reports and warranty returns, and how many days they take to reach the person who decides on a Section 15(b) report.
This quarter
- Run a mock range: pick a past changeover, draw ranges A, B and C as in the example, and price them at the product's retail price.
- Where B or C is several times A, move the label to a day or shift code, or add a pallet or carton mark that maps to line and shift.
- Join the line record to the ERP genealogy on line and time, and test that a range can be split by plant, warehouse, retailer and consumer within the ten days 16 CFR 1115.14(d) allows.
- For EU sales, check that each product's type, batch or serial number under GPSR Article 9(5) maps to a production period, not only to a shipment.
Root cause and corrective action after the range is set are covered in 8D problem solving and CAPA in manufacturing; the difference between tracing a lot and its full history is in traceability vs genealogy.
The line record behind a narrow range
Every range on this page is drawn from one of three records: the label, the shipping file, or the production record that says which product ran on which line between which changeovers. The first two are always there. The third decides whether a notice reads “model” or names a window.
Fabrico is a cloud OEE and light MES platform. It shows OEE and losses by machine, line and shift, with data from the machine's PLC or a Fabrico IoT device, and operators give the reason for a stop at the machine. With the selling price and margin of each SKU entered, losses are priced in money. The line record shows when each product ran on which line, how many units it made, and its stops and changeovers, so a window from one changeover to the next can be read and counted. On manual stations, AI cameras (an add-on) count output. Lot, serial and date code genealogy stays in the ERP or traceability system, and the two join on the line and the time. Plants building appliances and furniture can see how this applies in OEE software for consumer goods manufacturing; the building blocks are OEE software and a light MES.
Book a demo and see OEE and losses per line and shift.
What people ask next
How fast does a manufacturer have to report a product defect to the CPSC?
Within 24 hours of obtaining information that reasonably supports the conclusion that a report is due: that is what "immediately" means in 16 CFR 1115.14(e). The rule expects information to reach the responsible official in no more than 5 days and an investigation to take no more than 10 days, unless a longer period is reasonable. The duty in Section 15(b) applies to manufacturers, distributors and retailers alike.
What is the CPSC Fast Track recall program?
A route for firms that report and are ready to put a corrective action plan into effect within 20 working days. In return, CPSC staff do not make a preliminary determination that the product has a defect creating a substantial product hazard. The firm must stop sale and distribution at once, and products that may violate mandatory standards are not handled through Fast Track. Cummins, Lithonia, Char-Broil and AGA Rangemaster recalls in this tracker carry the Fast Track label.
Does a product recall have to offer a refund?
Not always. In the United States, 15 U.S.C. 2064(d) names repair, replacement with a like or equivalent product, or a refund of the purchase price, less a reasonable allowance for use after a year. In the EU, Article 37 of Regulation (EU) 2023/988 requires a choice between at least two of repair, replacement and an adequate refund, and a refund at least equal to the price paid. Of 92 CPSC recalls of durable goods from August to November 2026, 64 offered a refund.
How is the number of recalled units counted?
The full report under 16 CFR 1115.13(d) asks for the total number of units, the dates they were manufactured, distributed and sold, and the count at each level: manufacturer or importer, distributors, retailers and consumers. The notice prints one number, but units still in a plant, warehouse or store can be held, and only units with consumers need the public notice to reach them.
What product identification does the EU require for a recall?
Under Article 9(5) of the General Product Safety Regulation, manufacturers put a type, batch or serial number on the product. A recall notice under Article 36 identifies the product with identification numbers such as a batch or serial number. In 59 Safety Gate alerts on appliances, machinery, lighting and furniture read for this tracker, 9 gave a batch number.
How can a manufacturer narrow a recall range?
With a production record that shows which product ran on which line between which changeovers, and a label that maps to it. In the Example plant on this page, one fault covers 31,348 units by the line record, 73,816 by a monthly date code and 163,702 by shipping dates, a refund exposure of US$2,194,360 to US$3,448,280 against up to US$18,007,220.
Sources
All sources accessed on 18 November 2026. Dates are recall, release or publication dates where a page gives one; other dates are labelled as what they are.
- U.S. Consumer Product Safety Commission, recalls database (Recall Retrieval Web Services), recall dates 1 August to 18 November 2026, data as of 18 November 2026
- CPSC, Cummins Recalls Portable Generators Due to Risk of Serious Injury from Fire and Burn Hazards (27-087), recall date 12 November 2026
- CPSC, Little Giant Recalls Ladders with Rapid Locks Due to Risk of Serious Injury from Fall Hazard (27-067), recall date 5 November 2026
- CPSC, DREO Recalls DR-HSH015 Space Heaters Due to Fire and Burn Hazards (27-054), recall date 29 October 2026
- CPSC, Lithonia Lighting Recalls RSX Luminaires with Adjustable Tilt Arm Mountings (27-041), recall date 22 October 2026
- CPSC, Char-Broil Recalls Bistro Pro Electric Grills Due to Risk of Electric Shock (26-773), recall date 17 September 2026
- CPSC, Dual Fuel Ranges Recalled Due to Risk of Serious Injury or Death from Fire or Explosion Hazards; Manufactured by AGA Rangemaster (26-756), recall date 10 September 2026
- CPSC, Branch Recalls Ergonomic Chairs Due to Fall Hazard (26-735), recall date 3 September 2026
- CPSC, Walmart Reannounces Recall of Mainstays Nine-Drawer Fabric Dressers (26-726), recall date 27 August 2026
- CPSC, Fast Track Questions, undated page
- CPSC, CPSC Fast Track Recall Program, undated page
- 15 U.S.C. 2064, Substantial product hazards (Cornell Law School, Legal Information Institute), current text
- 16 CFR 1115.13, Content of a section 15(b) report (Cornell Law School, Legal Information Institute), current text
- 16 CFR 1115.14, Time computations (Cornell Law School, Legal Information Institute), current text
- Regulation (EU) 2023/988 on general product safety (EUR-Lex), Articles 9, 36, 37 and 52, published 23 May 2023, applies from 13 December 2024
- European Commission, Safety Gate: the EU rapid alert system for dangerous non-food products, weekly reports 40 to 46 of 2026
- European Commission, Safety Gate alert OR/00119/26 (glass latte mug, Ireland), published 20 October 2026
- European Commission, Safety Gate alerts SR/03044/26 and SR/03045/26 (USB chargers, Hungary), published 22 and 28 October 2026
- U.S. Government Accountability Office, Consumer Product Safety Commission: Actions Needed to Improve Processes for Addressing Product Defect Cases (GAO-21-56), released 19 November 2020
Related articles
Latest from our blog

Real Fabrico tiles, sample data.