Fill Level Inspection Rejects: Read the Valve Pattern, Cut the Cost
In short
- Read the rejects by valve first: on a 40-valve filler each valve should carry about 2.5% of the underfill rejects. One valve far above that is a repair job, not a setting.
- Split true from false rejects: measure 40 rejected bottles a shift by weight. Good bottles in the bin point to foam at the beam, a leaning bottle, or a cap or label in the beam.
- Warm product foams: pure water at 20 °C holds about 36% less CO2 per bar than at 5 °C. Rejects that rise with product temperature hit every valve.
- Count rejects as quality loss: stops for a full reject table are availability loss. Only a slower filler is a performance loss.
- The money: on a sample line in Romania filling 24,000 bottles an hour, 0.45% rejects cost EUR 133.20 a shift and EUR 100,699 a year. Two valve repairs and a fix for false rejects save EUR 49,382 a year.
Fill level inspection rejects are bottles that the inspector after the filler and capper pushes off the line because the liquid sits below the underfill limit or above the overfill limit.
Some are real underfills from one bad filling valve, from foam or from warm product. Some are good bottles the inspector misread.
To read them, tag every reject with its filling valve, audit the reject bin by volume, count rejects in the right OEE factor and price them per shift. Then fix the cause instead of raising the fill target on every bottle.
One 0.5 L PET soft drink line in Romania runs through every step below.
How the inspector measures: x-ray, gamma, HF and camera
Every fill level inspector answers one question: is there liquid at the fill height, and if not, how far off is it? The method decides which containers it can read and what fools it.
| Method | What it reads | Containers | What can cause false rejects |
|---|---|---|---|
| X-ray | How much of an x-ray beam the contents absorb at the fill height | Glass, PET, cans | Foam at the beam, a bottle off-centre, a set-up for another product |
| Gamma | The same principle, with a small sealed radioactive source | Glass, PET, cans | Foam at the beam, a bottle off-centre |
| High frequency (HF) | How water-based liquid changes an electric field at the fill height | Glass and PET, not metal cans | Foam, a water film or condensation on the wall, a label at sensor height |
| Camera | The liquid line against a backlight | Clear or translucent containers | Foam, droplets, condensation, a label edge, a tilted bottle |
| Checkweigher | The weight of the full container | Any | Tare variation, vibration, bottle spacing |
X-ray and gamma units both use ionising radiation, so national rules built on Council Directive 2013/59/Euratom apply. A gamma unit holds a sealed source, which the directive defines as "a radioactive source in which the radioactive material is permanently sealed in a capsule".
Ask the supplier and the national regulator what notification, registration or licence the site needs before choosing either.
A checkweigher weighs instead of looking, so foam and bottle shape do not fool it. Its own reject rules are in checkweigher rejects in OEE quality.
A level is not a volume
A level filler with vent tubes or probes fills every bottle to the same height. A PET bottle with a slightly larger body then holds more at the same level. Calibrate the inspector on your own bottles: fill ten to known volumes by weight, read the level of each and keep the table.
The valve-by-valve reject pattern
A rotary filler is a ring of small fillers on one carousel. Quality engineers call this a multiple stream process, "a process that generates several streams of output".
A filling process "where a filler machine may have many heads" is their classic example (Epprecht, Barbosa and Simões, Production, 2011).
The same paper adds that when special causes "affect one stream at a time, disturbances are likely to occur first in only one stream". In plain words: when one valve wears, its rejects climb long before the filler average moves.
A one-year study of a 12-piston jar filler in a Polish food plant saw the same thing. Piston 8 was most often the highest filler (8 times) and piston 9 most often the lowest (7 times).
Many extremes on one piston, the author writes, point to "a problem with that particular filling piston" (Knop, 2023).
How to build the valve table
- Tag each reject with its valve. Where the inspector behind a rotary filler takes a reference signal at valve 1, it can assign each bottle to its filling valve and capper head. Ask the supplier how yours does it.
- Collect at least a week. One shift is too few: 640 underfills spread evenly over 40 valves is only 16 each.
- Work out each valve's share: rejects on that valve divided by all underfill rejects. On 40 valves an even share is 2.5%.
- Flag the outliers. A valve at, for example, three times its even share on most shifts goes on the repair list.
- Prove it with a swap. Move the suspect vent tube or seal to a good valve. If the rejects move with the part, the part is the cause.
The sample line from the worked example below shows what the table looks like when two valves are bad:
| Valve | Underfills per shift | Share | Against an even 2.5% |
|---|---|---|---|
| Valve 17 | 230 | 35.9% | Over 14 times: repair |
| Valve 32 | 70 | 10.9% | Over 4 times: repair |
| Each of the other 38 | About 9 | About 1.4% | Below an even share |
| All 40 valves | 640 | 100% | Even share: 16 each |
Two valves make 300 of the 640 underfills. No setting on the inspector and no change to the filler target fixes that. A technician with a seal kit does.
Seven reject patterns and the first check
The counters by hour, by shift and around stops show the rest. Start from the pattern, then go to the floor.
| Pattern in the counters | Likely cause | First check | Owner |
|---|---|---|---|
| One valve far above 2.5%, every shift | Worn valve seal, bent or wrong vent tube, sticky valve | Inspect and swap parts with a good valve | Maintenance |
| One capper head well above the rest | Cocked caps, or a head that knocks the bottle and makes it foam | Head alignment and torque; watch bottles at that head | Maintenance |
| All valves, rising through the day | Product warming, so more CO2 breaks out as foam | Product temperature at the filler against the set point | Production |
| Bursts after each stop | Bottles that waited in the filler or capper, or a hard restart | Rejects in the first minutes after a restart | Production |
| All valves low at once for a few minutes | Product supply: bowl level or pressure, mixer or carbonator | Bowl level and pressure trend at that time | Production and maintenance |
| Rejects, but the bin audit finds full bottles | False rejects: position, beam height, cap or label in the beam, condensation | Measure 40 rejects; watch bottles at the inspector | QA and engineering |
| Rejects jump after a changeover | Inspector still set for the old bottle, closure or product | Compare the inspector recipe with the run | QA |
Read the table from the top. The first two rows are repairs with a clear owner. The next three are process problems that hit every valve. The last two are inspector problems: the filler is fine and the bin holds good product.
Foam, CO2 and product temperature
A carbonated drink is filled under counter-pressure. When the bottle leaves the valve and the pressure drops to air, some CO2 comes out of solution. Warm product releases more, so it foams more.
The reason is solubility. NIST lists a Henry's law constant for CO2 in water of 0.035 mol/(kg bar) at 25 °C, with a temperature dependence constant of 2400 K (NIST Chemistry WebBook). From those two figures, pure water at 20 °C holds about 36% less CO2 per bar than at 5 °C.
Foam costs twice. Foam that rises out of the neck during the pressure release or at the capper takes product with it, so the bottle really is low. Foam still sitting at the measuring height when the bottle reaches the inspector can shift the reading.
When rejects follow temperature or time of day, check these in order:
- Product temperature at the filler, logged by the hour, against the set point agreed with the filler supplier.
- Carbonation against the recipe. More CO2 than specified behaves like warm product.
- Pressure release (snift) and fill speed settings for each product, after any recipe change.
- Bottle handling between filler and inspector. A hard transfer or a jerky conveyor shakes the bottle.
- Time to the inspector. If foam has not settled when the bottle reaches the beam, the inspector reads foam.
Slowing the filler can calm foam, but it costs speed on every bottle. At 22,000 instead of 24,000 bottles an hour the line loses 8.3% of its speed: 13,333 bottles in a 400-minute run. Compare that with the price of more product cooling before making it permanent.
False rejects: bottle position, cap and label in the beam
A false reject is a good bottle in the bin. The only way to know is to measure. Once a shift, take 40 bottles from the reject table, weigh each, subtract the empty bottle and cap, and convert to volume with the product density at 20 °C.
EU law says volume is "measured at or corrected to a temperature of 20 °C" (Directive 76/211/EEC, Annex I), so use the density at 20 °C.
Check these causes of good bottles in the bin:
- Bottle position. A bottle that leans on a guide, wobbles after a transfer or arrives tight against its neighbour shows its level at an angle. Light PET bottles on a wet conveyor are prone to it.
- Beam or sensor height. If the measuring height moves after a knock or a changeover, every bottle reads low or high by the same amount.
- Cap in the beam. When the fill height sits close to the closure, a cap seated high or cocked can reach the measuring zone.
- Label in the beam. Where the inspector sits after the labeller, a sleeve or label at the measuring height blocks a camera and can shift an HF reading.
- Condensation and droplets. Cold-filled bottles sweat in a warm hall. Water on the wall confuses a camera and an HF sensor.
- Wrong recipe. A limit taught on another bottle, closure or product rejects good bottles from the first minute.
Check the reject device too. If it fires early or late, it pushes the neighbour of the bottle that failed. Run a known low bottle through at full speed and watch which bottle leaves the line.
The legal floor: average system and TNE for a 500 ml bottle
In the EU, e-marked prepackages follow the average system of Directive 76/211/EEC. Its Annex I sets three rules for each batch:
- "the actual contents shall not be less, on average, than the nominal quantity";
- the share of packs short by more than the tolerable negative error (TNE) must be small enough to pass the reference test in Annex II;
- no pack short by more than twice the TNE may carry the e-mark.
Drinks sit in the same directive. The old liquids directive, 75/106/EEC, was repealed from 11 April 2009 by Directive 2007/45/EC, which also deleted the exception for it from Article 1 of 76/211/EEC.
For a 500 ml bottle the TNE is 15 ml. The directive's table gives 3% for 300 to 500 ml and 15 ml for 500 to 1,000 ml, so both rows give 15 ml at 500. The GB guidance from the Office for Product Safety and Standards uses the same table (OPSS packaged goods guidance).
| Limit | Volume | What it means |
|---|---|---|
| Nominal (Qn) | 500 ml | The batch average must reach this |
| T1 = Qn - TNE | 485 ml | Only a small share may fall below |
| T2 = Qn - 2 TNE | 470 ml | None below this may carry the e-mark |
Two points matter for the inspector. First, it is a control tool. The GB guidance says packers must either measure every package or check by sampling, and keep records of sample checks. Ask the national legal metrology authority before treating level readings as that proof.
Second, the spread sets the target. The GB guidance says: "Where the variability exceeds 0.5 TNE then the target quantity always needs to exceed the nominal (labelled) quantity". For 500 ml that is a standard deviation above 7.5 ml.
The same guidance sets the target as the largest of Qn, Qn - TNE + 2s and Qn - 2TNE + 3.72s, where s is the standard deviation. With s at 9 ml that is 503.5 ml: 3.5 ml of giveaway on every bottle.
One valve that fills low widens s for the whole filler. That is why valve repairs come before target changes. The cost of filling above the label is covered in giveaway and overfill as a quality loss.
Rejects in OEE: quality, availability or filler performance
Fill level rejects touch each OEE factor in a different way. Agree the rule once, put it in the reason list and keep it the same on every line.
| Event | OEE factor | Count it as |
|---|---|---|
| Underfilled or overfilled bottle rejected and emptied | Quality | Scrap, reason "underfill" or "overfill" |
| Good bottle rejected and emptied | Quality | Scrap, reason "false reject" |
| Good bottle re-checked and put back before the count | None | Good output, counted once |
| Line stopped because the reject table is full | Availability | Stop, reason "reject table full" |
| Filler slowed to calm foam | Performance | Speed loss against 24,000 an hour |
Two traps are common. First, the filler counter counts every filled bottle, rejects included. Count good output after the inspector, or subtract the inspector's rejects, or quality will look perfect.
Second, a bad valve is not a filler performance loss. The filler ran at full speed; it filled some bottles wrong. Book the loss in quality and keep the valve table from the inspector next to it, so maintenance sees where it comes from.
The reject-table stop hides inside short stops unless it has its own reason. The operator logs "reject table full" as the stop reason, set up in the reason list. Log it once, on the machine whose OEE the line reports.
The rest of the filler's losses are in filler OEE on a bottling line. Plants comparing tools for counting at 400 bottles a minute can start with OEE software for high-speed packaging lines.
Worked example: 0.5 L PET soft drinks in Romania
One line in Romania fills 0.5 L PET bottles of carbonated soft drink on a 40-valve rotary filler with a capper, rated at 24,000 bottles an hour. A fill level inspector after the capper and before the labeller rejects underfills and overfills onto a reject table. The line runs three shifts.
Lines like it are common: UNESDA counts over 500 soft drinks production and bottling plants across Europe (UNESDA progress report, July 2026).
The numbers are an example, not a customer's data. The labour cost is Eurostat's; the rest are sample figures to replace with your own.
| Input | Value | Basis |
|---|---|---|
| Rated speed | 24,000 an hour (400 a minute) | Sample |
| Run time; planned time per shift | 400 min; 450 min | Sample |
| Bottles filled and inspected per shift | 160,000 | 400 min x 400 a minute |
| Shifts | 3 a day, 21 days: 63 a month, 756 a year | Sample |
| Rejects per shift | 640 underfill + 80 overfill = 720 (0.45%) | Sample: two weeks of counters |
| Value of one rejected bottle | EUR 0.16: drink 0.06, PET bottle 0.08, cap 0.02 | Sample figures |
| Reject table | Full at 120 bottles; 3 min stop to empty | Sample |
| Line crew | 5 people | Sample |
| Labour cost | EUR 12.00 an hour | Eurostat lc_lci_lev, Romania, manufacturing, 2025 |
In this sample the empty bottle and cap cost more than the drink in them, so a reject wastes packaging as much as product.
What the counters and the bin audit show
The valve table above is this line: valves 17 and 32 make 300 of the 640 underfills, and the other 38 valves make 340.
The bin audit adds the false rejects: 1 in 8 rejects, 90 a shift, is a good bottle inside the limits, rejected because of foam at the beam and bottles leaning on the guide.
That leaves 330 other true rejects: the 340 underfills on the other valves plus the 80 overfills, minus the 90 false ones.
Cost per shift today
- Bottles lost: 720 x EUR 0.16 = EUR 115.20.
- Reject-table stops: 720 / 120 = 6 stops x 3 min = 18 min. Crew idle: 5 x 18 = 90 min = 1.5 h. 1.5 x EUR 12.00 = EUR 18.00.
- Total: 115.20 + 18.00 = EUR 133.20 per shift.
Per month: EUR 133.20 x 63 = EUR 8,391.60. Per year: EUR 133.20 x 756 = EUR 100,699.20. In OEE terms, 18 of 450 planned minutes is 4.0 points of availability, and 720 of 160,000 bottles is a 0.45% quality loss.
If the line is sold out, the stops cost far more than idle labour. 18 minutes at 400 bottles a minute is 7,200 bottles not made per shift. Multiply by your margin per bottle.
The fix and its cost
- Repair valves 17 and 32 in the planned cleaning window: seal kit and vent tube EUR 120 per valve (sample figure) plus 2 technician hours at EUR 12.00. That is EUR 144 per valve, EUR 288 for both.
- Stop the false rejects: adjusting the guide at the inspector and smoothing the transfer before it brings them from 90 to 20 a shift (sample result). Internal hours only.
After the fix
- Rejects: valves 17 and 32 drop to about 9 each, like the others: 18. False rejects: 20. Other true rejects stay at 330. Total: 368 a shift (0.23%).
- Bottles lost: 368 x EUR 0.16 = EUR 58.88.
- Stops: 368 / 120 = 3 full tables x 3 min = 9 min. 5 x 9 = 45 min = 0.75 h x EUR 12.00 = EUR 9.00.
- Total: EUR 67.88 a shift, EUR 4,276.44 a month, EUR 51,317.28 a year.
The saving is EUR 65.32 a shift: EUR 4,115.16 a month and EUR 49,381.92 a year. The EUR 288 repair pays back in under five shifts. Even with two valve repairs every month (EUR 3,456 a year), the net gain is EUR 45,926 a year, if the gain holds.
Compare that with the workaround for a low valve: raising the target on all 40. In this example, 1 ml more on every bottle is 160 litres of drink a shift.
At EUR 0.12 a litre, the sample drink cost, that is EUR 19.20 a shift and EUR 14,515.20 a year, and valve 17 still fills low.
Decision: reject limit, filler target or valve repair
Measure before you change anything. A week of counters by valve, a bin audit every shift and a product temperature log tell you which row of the pattern table you are in. Without them, every fix sounds right.
That record is easier to keep on the same screen as stops and output. OEE software or a light MES that counts the reject signal from the line PLC shows rejects by shift and hour next to the reject-table stops, from machine signals rather than paper.
What you see: a shift timeline, unclassified time waiting for a reason, and the operator's line-down screen, on sample lines. Book a demo.
Plays from YouTube. Google may set cookies when you press play. Privacy policy.
For the wider picture of such systems in bottling plants, see MES for beverage manufacturing.
| Option | What it fixes | Cost | Pick it when |
|---|---|---|---|
| Repair the outlier valves | Underfills from one or two valves | Parts and technician hours: EUR 288 for two valves in the example | One or two valves carry far more than 2.5% each |
| Set up the inspector again | False rejects | Internal hours | The bin audit finds good bottles |
| Cool the product or correct CO2 and snift | Foam on every valve | Ask the filler or cooler supplier for a price | Rejects follow product temperature or time of day |
| Slow the filler | Foam nothing else cures | 8.3% of speed at 22,000 an hour | Only as a stopgap while the cause is fixed |
| Raise the filler target | A sampled average below 500 ml | EUR 19.20 a shift per ml in the example | The sampled average fails; never to cover one valve |
| Change the inspection method | A container or foam the current unit cannot read | Ask the supplier for a price per line | The container or the product rules out the current method |
| Line software | Rejects, stops and money on one screen | Ask the vendor for a price per line per month | Counters are reset each shift and nobody prices them |
Setting the reject limits
- Underfill limit, safe floor: T1 (485 ml) plus the inspector's repeatability at line speed, turned into a level on your calibrated bottles. The sample line uses 490 ml.
- Tighter than that only for a reason you can name, such as how clear PET bottles look side by side on the shelf. Every ml of tightening throws away legal bottles.
- Overfill limit: set from the headspace the closure and the product need, agreed with the filler and closure suppliers.
- Filler target: from the sampled average and spread, by the GB guidance formula above. Raise it only when the sampled average fails.
Who should pick which
- QA manager: owns the limits, the bin audit, the legal sampling and the records.
- Maintenance lead: owns valve and capper head repairs from the valve table.
- Production manager: owns product temperature, carbonation, filler speed and the reject-table stop reason.
- Plant manager: signs capital for cooling or a new inspector against the cost per year.
Questions to ask the inspector supplier
- Can every reading be tagged with its filling valve and capper head, and how does the unit take the valve 1 signal from the filler?
- What is the repeatability in ml on this bottle at 24,000 bottles an hour?
- How does it read a bottle with foam at the measuring height? Show it on the foamiest product, not on water.
- Which containers can it read (PET, glass, cans), and what has to change at each changeover?
- Does it confirm that each rejected bottle left the line, and does it give reject and table-full signals to the line PLC?
- For x-ray or gamma: what notification, registration or licence does the site need, and who does the radiation surveys?
- How are limits, calibrations and setting changes logged, and how does that record leave the unit?
Two weeks to a priced reject bin
Two weeks is enough to go from a full reject table to a valve list, a split of true and false rejects and a price per shift. The floor card below is the plan in five steps; print it for the line.

Text version of the diagram
- Days 1-3, pull the counters: underfill, overfill and total per shift; tag each reject with its valve and capper head; log reject-table-full stops on their own.
- Days 4-7, find the valve pattern: on 40 valves an even share is 2.5% each; three times the even share on most shifts means repair; all valves rising together means foam or temperature.
- Every day, audit the reject bin: weigh 40 rejects and convert at 20 °C; good bottles in the bin are false rejects; check bottle position, beam height, cap and label.
- Week 2, fix one cause at a time: repair outlier valves in the cleaning window; then the inspector, then product cooling; re-check the valve table after each fix.
- Day 14, set limits and price it: for 500 ml the TNE is 15 ml, T1 485 ml and T2 470 ml; never raise all 40 valves to cover one; bottles plus stop minutes in EUR per shift.
Fix the valve before you move the target.
Where Fabrico fits
Fabrico is OEE software and a light MES with computer vision. Fabrico is made by the publisher of this article. On this topic it does the counting and the pricing; the valve table stays in the inspector.
- OEE by line and shift from the core machine, here the filler, with analytics by hour, shift, day, week and month.
- A reject signal from the line PLC is counted like any machine signal; where there is none, the reject count can be entered by product and reason.
- Scrap is recorded by product and reason, so underfills, overfills and false rejects stay apart.
- The operator logs "reject table full" as the stop reason, set up in the reason list, in a few taps at the machine.
- With the selling price and margin of each product entered, losses are priced in money and stops are ranked by financial impact.
- The camera add-on is not a fill level inspector: where a camera covers the line it counts output, for example at a station with no usable signal.
See OEE with computer vision, or pricing: one quote per plant, by machines and modules.
Sources, accessed 26.11.2026: EUR-Lex, Council Directive 76/211/EEC on prepackaged products, consolidated text of 26.07.2019; EUR-Lex, Directive 2007/45/EC on nominal quantities for prepacked products; EUR-Lex, Council Directive 2013/59/Euratom, basic safety standards against ionising radiation; GOV.UK, Office for Product Safety and Standards, Packaged Goods Regulations 2006: Guidance (GB), version 3; Epprecht, Barbosa and Simões, SPC of multiple stream processes, Production 21(2), 2011, DOI 10.1590/S0103-65132011005000022; Knop, Statistical multivariate analysis of the dosing process results, Scientific Papers of Silesian University of Technology 176, 2023, DOI 10.29119/1641-3466.2023.176.17; NIST Chemistry WebBook, Carbon dioxide, Henry's law data; UNESDA Soft Drinks Europe, Progress report on EU Agri-Food Code commitments, July 2026; Eurostat, Labour cost levels by NACE Rev. 2 activity (lc_lci_lev), Romania, manufacturing, 2025.
Frequently asked questions
What is an acceptable reject rate for a fill level inspector?
No regulator publishes one figure. Set a target per product from two weeks of your own counters, then price it: on the sample line in this article, 0.45% rejects cost EUR 100,699 a year and 0.23% cost EUR 51,317.
Why does one filling valve cause a large share of the underfill rejects?
On a 40-valve filler each valve should carry about 2.5% of the rejects. For a valve far above that, check for a worn seal, a bent or wrong vent tube, or a sticking valve. Repair it; do not raise the target on all 40 valves.
Why does the fill level inspector reject full bottles?
Foam at the measuring height, a bottle leaning on a guide, a cap or label in the beam, condensation, or a recipe set for another bottle. Weigh 40 rejects a shift and convert at 20 °C to split true from false rejects.
How much can a 500 ml bottle be underfilled legally?
Under the EU average system the batch average must reach 500 ml. Only a small share may be short by more than the TNE of 15 ml, and no bottle short by more than 30 ml may carry the e-mark.
Do fill level rejects count against filler performance in OEE?
No. Rejected bottles are quality loss and stops for a full reject table are availability loss. Only running the filler slower than its rated speed, for example to calm foam, is a performance loss.
Does warm product cause more underfill rejects?
It can. CO2 is less soluble in warmer water, so warm product releases more gas when the pressure drops and foams more at the valve and the capper. Log product temperature by the hour next to the reject counters.
Which fill level inspection method suits a PET line?
Clear PET can be read by x-ray, gamma, HF or camera; cans rule out HF and camera. X-ray and gamma add radiation rules. Run a trial on the foamiest product before choosing.
Put a price on the reject table. A demo shows OEE by line and shift from the core machine, scrap by product and reason, and losses priced in money from the prices and margins you enter.
Latest from our blog

Real Fabrico tiles, sample data.